一、问题:requested timeline %u does not contain minimum recovery point %X/%X on timeline %u
该日志在代码中的位置如下:
StartupXLOG:
if (!XLogRecPtrIsInvalid(ControlFile->minRecoveryPoint) &&
tliOfPointInHistory(ControlFile->minRecoveryPoint - 1, expectedTLEs) !=
ControlFile->minRecoveryPointTLI)
ereport(FATAL,
(errmsg("requested timeline %u does not contain minimum recovery point %X/%X on timeline %u",
recoveryTargetTLI,
(uint32) (ControlFile->minRecoveryPoint >> 32),
(uint32) ControlFile->minRecoveryPoint,
ControlFile->minRecoveryPointTLI)));
二、分析
recoveryTargetTLI这个值是什么呢?
1、改值在启动恢复过程中变化如下:
StartupXLOG:
...
if (ControlFile->minRecoveryPointTLI > ControlFile->checkPointcopy.ThisTimeLineID)
recoveryTargetTLI = ControlFile->minRecoveryPointTLI;
else
recoveryTargetTLI = ControlFile->checkPointcopy.ThisTimeLineID;
readRecoveryCommandFile();
|-- for (item = head; item; item = item->next){
| ...
| else if (strcmp(item->name, "recovery_target_timeline") == 0){
| rtliGiven = true;
| if (strcmp(item->value, "latest") == 0)
| rtli = 0;
| else
| rtli = (TimeLineID) strtoul(item->value, NULL, 0);
| }
| ...
| }
| ...
| if (rtliGiven){
| if (rtli){
| recoveryTargetTLI = rtli;
| recoveryTargetIsLatest = false;
| }else{
| recoveryTargetTLI = findNewestTimeLine(recoveryTargetTLI);
| recoveryTargetIsLatest = true;
| }
|-- }
首先,pg_control文件记录的最小恢复点时间线ControlFile->minRecoveryPointTLI会和pg_control文件记录的checkpoint的的时间线 ControlFile->checkPointcopy.ThisTimeLineID比较,recoveryTargetTLI取两者之间较大值。
然后readRecoveryCommandFile会读取recovery.cnf文件,如果是主机则没有recovery.cnf文件。recovery.cnf文件中recovery_target_timeline的值指定恢复到的时间线,如果是latest则时间线rtli为0否则为其指定值;如果rtli是指定值,则recoveryTargetTLI为指定值,否则从第一步获取的recoveryTargetTLI值+1开始,看是否有其对于的history文件,找到最大时间线对于的history文件,recoveryTargetTLI为该时间线。
版权声明:本文内容由互联网用户自发贡献,该文观点与技术仅代表作者本人。本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌侵权/违法违规的内容, 请发送邮件至 [email protected] 举报,一经查实,本站将立刻删除。